| Category |
A |
B |
C |
D |
| Year |
0-10 years |
0-20 years |
20+ years |
20+ years |
| Hours |
0-5,000 hrs |
0-10,000 hrs |
0-15,000 hrs |
All D units are as is |
| Radiator |
no leaks, dry no damage |
no leaks, dry |
no leaks |
| Engine |
no leaks good runs RPM checked |
runs good oil pressure RPMs
w/in spec no oil leaks blow-by and not excesv. |
runs |
| Batteries |
starts easily |
starts |
turns over |
| Transmission |
no leaks shifts trks. straight |
mechanically correct no oil leaks |
mechanically working |
| Finals |
no leaks, dry |
no oil leaks |
min. leaks |
| U/C overall |
70% of new |
50% of new |
25% of new |
| Blade face |
70% of new |
holes=new face |
holes patched |
| Blade p&b |
75% of new |
50% of new |
25% of new |
| Cutting edge |
60% of new |
50% of new |
25% of new |
| Hydraulics |
no leaks pressures checked |
no external leaks |
operational leaks won't drip w/in 5 min. of
sitting |
| Cylinders |
no int. or ext. leaks |
no external leaks |
min. ext. leaks |
| Attach/pins |
75% of new |
75% of new |
25% of new |
| Draw bar |
required |
not required |
not required |
| ROPS |
required |
required |
required if 1969/newer |
Cab/glass seat/belt |
good cond. all repaired |
good cond. working seat |
cab cleaned seat useable recov. if nec. |
| Metal |
no damageside shlds. & grills on core prdcts. |
minor damage |
minor damage |
Electrical b/u alarm |
all works |
oil pressure water temp. trans. temp. b/u alarm neutral start |
starts/runs |
| Fluids/filters |
completely serviced |
svc. as needed chg. eng. oil & filter |
checked |
| Paint |
90% plus |
75% plus |
25% plus |
Minor damage=small dents, no tears in metal, side shields,
and grills on core products.
Oil leak=any oil dripping or washing area clean after five minutes of operation at normal operating temperature. Dust build up
around area does not constitute an oil leak. |

Crawler Dozer Criteria |
Wheel Loader Criteria |
Excavator Criteria |
Tractor Loader Backhoe Criteria
|
 |
|